Solar and storage hybrid inverters
ASW H-T2/T3 Leo Pro Series
Three-phase hybrid inverter (DG version), 5–15kW
ASW H-T2/T3 Leo Pro series three-phase hybrid inverter, 5–15kW (DG version), for solar-plus-storage systems.
- Max. PV array power7500 Wp / 9000 Wp etc. 6 types
- Max. input voltage1100 V
- MPP voltage range / rated input voltage150 V - 950 V / 630 V
- Min. input voltage / start voltage60 V / 180 V
Max. PV array power
7500 Wp / 9000 Wp etc. 6 types
Max. input voltage
1100 V
MPP voltage range / rated input voltage
150 V - 950 V / 630 V
Min. input voltage / start voltage
60 V / 180 V
Warranty
10 years
Product description
- 5–15kW
- 3P
- 2–3MPPT
- with AI smart dongle LAN/WLAN
- 20A*2Only ASW05kH-T2-DG, ASW06kH-T2-DG, ASW08kH-T2-DG, ASW10kH-T2-DG…
- DC with SPD surge protection
- AC with MOV surge protection
- DC PV port (PV Pot) with Sunclix connector
- DC battery port (Bat Pot) with MC4 connector
- AC grid port (Grid Pot) with Vaconn connector
- AC backup port (EPS Pot) with Vaconn connector
- AC generator port (GEN Pot) with Vaconn connector
- with AFCI (arc-fault protection)
- 3-phase 4-wire
- with Modbus TCP
- Morandi blue
- 16A*3Only ASW08kH-T3-DG, ASW10kH-T3-DG, ASW12kH-T3-DG, ASW15kH-T3-DG
OVERVIEW
ASW H-T2/T3 Leo Pro Series
ASW H-T2/T3 Leo Pro series three-phase hybrid inverter, 5–15kW (DG version), for solar-plus-storage systems.
SPECIFICATIONS
Product comparison
ModelASW H-T2/T3 Leo Pro Series
| Product comparison | |||
|---|---|---|---|
| PV input | |||
| Max. PV array power | 7500 Wp | 9000 Wp | 12000 Wp |
| Max. input voltage | 1100V | 1100V | 1100V |
| MPP voltage range / rated input voltage | 150 V - 950 V / 630V | 150 V - 950 V / 630V | 150 V - 950 V / 630V |
| Min. input voltage / start voltage | 60 V / 180V | 60 V / 180V | 60 V / 180V |
| No. of independent MPPT trackers / strings per MPPT input | 2 / 1 | 2 / 1 | 2 / 1 |
| Max. input current / Max. power per MPPT tracker | 20 A / 7500W | 20 A / 9000W | 20 A / 10000W |
| Max. short-circuit current per MPPT tracker | 30A | 30A | 30A |
| Battery input | |||
| Battery voltage range | 120 V - 600V | 120 V - 600V | 120 V - 600V |
| Max. charging power from PV and AC grid | 12000W | 12000W | 12000W |
| Max. charging power from grid | 5000W | 6000W | 8000W |
| Max. discharge power | 5000W | 6000W | 8000W |
| Max. charge / discharge current | 50A | 50A | 50A |
| Battery type | LiFePO4 | LiFePO4 | LiFePO4 |
| AC input | |||
| Rated grid voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V |
| Rated grid frequency | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| Max. input power from grid | 10000W | 12000W | 16000W |
| Max. input current from grid | 14.5A | 17.4A | 23.2A |
| AC output | |||
| AC voltage range / Nominal AC voltage | 270 V - 480 V / 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 270 V - 480 V / 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 270 V - 480 V / 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V |
| Rated AC grid frequency | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| AC grid frequency range | 45 Hz - 55 Hz / 55 Hz - 65 Hz | 45 Hz - 55 Hz / 55 Hz - 65 Hz | 45 Hz - 55 Hz / 55 Hz - 65 Hz |
| Rated apparent power | 5000VA | 6000VA | 8000VA |
| Max. apparent power | 5500VA | 6600VA | 8800VA |
| Rated grid output current (@400 V) | 7.3A | 8.7A | 11.6A |
| Max. grid output current (@400 V) | 8.0A | 9.6A | 12.8A |
| Power factor at rated power / adjustable range | 1 / 0.8 leading - 0.8 lagging | 1 / 0.8 leading - 0.8 lagging | 1 / 0.8 leading - 0.8 lagging |
| Harmonics THD | < 3 % (of nominal power) | < 3 % (of nominal power) | < 3 % (of nominal power) |
| Power factor at rated power / adjustable displacement | 1 / 0.8 leading - 0.8 lagging | 1 / 0.8 leading - 0.8 lagging | 1 / 0.8 leading - 0.8 lagging |
| EPS output | |||
| Nominal output voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V |
| Nominal output frequency | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| Rated apparent power | 5000VA | 6000VA | 8000VA |
| Rated current (@400 V) | 7.3A | 8.7A | 11.6A |
| Max. current (@400 V, continuous on-grid / off-grid) | 14.5 A / 7.3A | 17.4 A / 8.7A | 23.2 A / 11.6A |
| Max. power on each phase (@400 V, continuous on-grid / off-grid) | 3333 W / 1667W | 4000 W / 2000W | 5333 W / 2667W |
| Peak output apparent power (@400 V, continuous on-grid / off-grid up to 10s) | 10000 VA / 10000VA | 12000 VA / 12000VA | 16000 VA / 16000VA |
| Max. switch time | < 10 ms | < 10 ms | < 10 ms |
| Output THDv (@ Linear load) | 2% | 2% | 2% |
| Generator side | |||
| Max. input apparent power | 7500VA | 9000VA | 12000VA |
| Max. charging power of battery | 5000W | 6000W | 8000W |
| Rated voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415V |
| Rated AC frequency | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| Efficiency | |||
| MPPT efficiency | 99.9% | 99.9% | 99.9% |
| European efficiency / Max. efficiency | 97.2 % / 98.0% | 97.5 % / 98.2% | 97.9 % / 98.4% |
| Safety protection | |||
| DC surge protection (Type II, according to EN/IEC 61643-11) | Standard | Standard | Standard |
| Insulation resistance detection | Standard | Standard | Standard |
| PV string input reverse polarity protection | Standard | Standard | Standard |
| Battery input reverse polarity protection | Standard | Standard | Standard |
| Ground fault monitoring | Standard | Standard | Standard |
| Residual current monitoring unit | Standard | Standard | Standard |
| AC short circuit protection | Standard | Standard | Standard |
| Anti-islanding protection | Standard | Standard | Standard |
| Arc fault circuit interrupter (AFCI) | Optional | Optional | Optional |
| General data | |||
| Dimensions (W / D / H) | 625 / 241 / 465mm | 625 / 241 / 465mm | 625 / 241 / 465mm |
| Weight | 28.0kg | 28.0kg | 28.0kg |
| Operating temperature range | -25°C - 60°C | -25°C - 60°C | -25°C - 60°C |
| Cooling concept | Natural convection | Natural convection | Natural convection |
| Noise emission | < 35 dB | < 35 dB | < 35 dB |
| Degree of protection (as per IEC 60529) | IP66 | IP66 | IP66 |
| Relative humidity | 100% | 100% | 100% |
| Max. operating altitude | 4000 m | 4000 m | 4000 m |
| Features | |||
| HMI | LED, App | LED, App | LED, App |
| BMS interface | CAN | CAN | CAN |
| Smart meter interface | RS485 | RS485 | RS485 |
| Communication interfaces | Dongle: Wi-Fi (2.4 GHz) / LAN (100 Mbps), Inverter: RS485 (Modbus RTU), LAN (100 Mbps, Modbus TCP only) | Dongle: Wi-Fi (2.4 GHz) / LAN (100 Mbps), Inverter: RS485 (Modbus RTU), LAN (100 Mbps, Modbus TCP only) | Dongle: Wi-Fi (2.4 GHz) / LAN (100 Mbps), Inverter: RS485 (Modbus RTU), LAN (100 Mbps, Modbus TCP only) |
| Digital output (dry contact) / No. of outputs | Standard / 2 | Standard / 2 | Standard / 2 |
| Digital input (dry contact) / No. of inputs | Standard / 4 | Standard / 4 | Standard / 4 |
| Integrated power control / export power control | Standard / Standard | Standard / Standard | Standard / Standard |
| Certificates and approvals (more available on request) | AS/NZS 4777.2, TOR Stromerzeugungsanlagen Typ A, C10/11, TR 3.3.1, FD Çt-819-11, EN 50549-1, EN 62109-1/-2, EN 60068-2-1/-2-2/-2-14, EN 62000-6-2/-4, EN 60068-2-x, VDE-AR-N 405, IEC 61683, IEC 62116, IEC 63027, NTS Type A, RD 647, UNE 217001, UNE 217002, NA: EE-AR-1, G99-1, PORTARIA N° 140 | AS/NZS 4777.2, TOR Stromerzeugungsanlagen Typ A, C10/11, TR 3.3.1, FD Çt-819-11, EN 50549-1, EN 62109-1/-2, EN 60068-2-1/-2-2/-2-14, EN 62000-6-2/-4, EN 60068-2-x, VDE-AR-N 405, IEC 61683, IEC 62116, IEC 63027, NTS Type A, RD 647, UNE 217001, UNE 217002, NA: EE-AR-1, G99-1, PORTARIA N° 140 | AS/NZS 4777.2, TOR Stromerzeugungsanlagen Typ A, C10/11, TR 3.3.1, FD Çt-819-11, EN 50549-1, EN 62109-1/-2, EN 60068-2-1/-2-2/-2-14, EN 62000-6-2/-4, EN 60068-2-x, VDE-AR-N 405, IEC 61683, IEC 62116, IEC 63027, NTS Type A, RD 647, UNE 217001, UNE 217002, NA: EE-AR-1, G99-1, PORTARIA N° 140 |
Product details