Grid-tied solar inverters
ASW HT Series 250–360kW
Three-phase grid-tied inverter, 250–360kW
ASW HT series three-phase grid-tied inverter, 250–360kW, for large ground-mounted plants.
- Max. input voltage1500 V
- MPP voltage range / rated input voltage500 V - 1500 V / 1080 V
- Min. input voltage500 V
- Start up input voltage550 V
Max. input voltage
1500 V
MPP voltage range / rated input voltage
500 V - 1500 V / 1080 V
Min. input voltage
500 V
Start up input voltage
550 V
Warranty
5 years
Product description
- 250–360kW
- 3P
- 5–6MPPT
- model without communication
- 5–6*75A
- DC-side SPD surge protection
- AC-side SPD surge protection
- with DC Amphenol H4 connector
- AC-side unspecified
- with PLC (power line carrier)
- with RS485
OVERVIEW
ASW HT Series 250–360kW
ASW HT series three-phase grid-tied inverter, 250–360kW, for large ground-mounted plants.
SPECIFICATIONS
Product comparison
ModelASW HT Series 250–360kW
| Product comparison | |||
|---|---|---|---|
| Input (DC) | |||
| Max. input voltage | 1500V | 1500V | 1500V |
| MPP voltage range / rated input voltage | 500 V - 1500 V / 1080V | 500 V - 1500 V / 1080V | 500 V - 1500 V / 1080V |
| Min. input voltage | 500V | 500V | 500V |
| Start up input voltage | 550V | 550V | 550V |
| Max. operating input current per MPP | 75A | 75A | 75A |
| Max. short circuit current per MPP | 113A | 113A | 113A |
| No. of independent MPPT inputs / strings per MPPT input | 5 / 5 | 5 / 5 | 6 / 5 |
| Output (AC) | |||
| AC output power | 250000 VA @ 50°C | 333000 VA @ 40°C | 352000 VA @ 40 °C, 325000 VA @ 50°C |
| AC nominal voltage | 800V | 800V | 800V |
| AC voltage range | 640 V - 920V | 640 V - 920V | 640 V - 920V |
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz |
| Max. output current | 198.5A | 240.3A | 254.0A |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging |
| Feed-in phases | 3 / 3-PE | 3 / 3-PE | 3 / 3-PE |
| THD | < 3% | < 3% | < 3% |
| Efficiency & Protection | |||
| Max. efficiency / European efficiency | 99.01 % / 98.8% | 99.01 % / 98.8% | 99.01 % / 98.8% |
| Smart DC switch | Standard | Standard | Standard |
| AC / DC temperature detection | Standard | Standard | Standard |
| Anti-islanding protection | Standard | Standard | Standard |
| AC overcurrent protection | Standard | Standard | Standard |
| DC reverse-polarity protection | Standard | Standard | Standard |
| AC short circuit protection | Standard | Standard | Standard |
| PV string monitoring | Standard | Standard | Standard |
| DC surge protection | Type II | Type II | Type II |
| AC surge protection | Type II | Type II | Type II |
| Residual Current Monitoring Unit (RCMU) | Standard | Standard | Standard |
| Ground fault monitoring | Standard | Standard | Standard |
| Grid monitoring | Standard | Standard | Standard |
| Anti-PID | Optional | Optional | Optional |
| General data | |||
| Dimensions (W / H / D) | 1,158 / 760 / 382mm | 1,158 / 760 / 382mm | 1,158 / 760 / 382mm |
| Weight | ≤ 116.0kg | ≤ 116.0kg | ≤ 117.0kg |
| Operating temperature range | -30°C - 60°C | -30°C - 60°C | -30°C - 60°C |
| Self-consumption (at night) | < 5W | < 5W | < 5W |
| Topology | Non-isolated | Non-isolated | Non-isolated |
| Cooling concept | Smart forced cooling | Smart forced cooling | Smart forced cooling |
| Protection degree | IP66 | IP66 | IP66 |
| Relative humidity | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) |
| Max. operating altitude | 5000 m (> 4000 m with derating) | 5000 m (> 4000 m with derating) | 5000 m (> 4000 m with derating) |
| Features | |||
| DC connector | DC Plug-in connector | DC Plug-in connector | DC Plug-in connector |
| AC connector | OT / DT Terminal (Max.500mm²) | OT / DT Terminal (Max.500mm²) | OT / DT Terminal (Max.500mm²) |
| Display | LED, Bluetooth + App | LED, Bluetooth + App | LED, Bluetooth + App |
| USB | Standard | Standard | Standard |
| Communication | RS485 / ABUS | RS485 / ABUS | RS485 / ABUS |
| Compliance | |||
| Certificates and approvals (more available on request) | IEC 62109-1/2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50549-2 | IEC 62109-1/2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50549-2 | IEC 62109-1/2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50549-2 |
Product details

APPLICATIONS
Suitable for Multiple Scenarios
From individual equipment to an integrated energy system. Explore a solution around your site and project needs.
Explore Solutions
LET’S TALK ENERGY
Ready to Power Your Business?
Get in touch with our team to discuss your project requirements and find the best solution for your needs.