Grid-tied solar inverters
ASW LT Series 125–150K
Three-phase grid-tied inverter, 125–150kW
ASW LT series three-phase grid-tied inverter, 125–150kW, for large ground-mounted plants.
- Max. PV array power187500 Wp STC
- Max. input voltage1100 V
- MPP voltage range / rated input voltage200 V - 1000 V / 630 V
- Min. input voltage200 V
Max. PV array power
187500 Wp STC
Max. input voltage
1100 V
MPP voltage range / rated input voltage
200 V - 1000 V / 630 V
Min. input voltage
200 V
Warranty
10 years
Product description
- 125–150kW
- 3P
- 8MPPT
- with AI smart dongle LAN/WLAN
- 48A*8
- DC with MOV surge protection
- AC with MOV surge protection
- DC with Vaconn connectorOnly ASW125K-LT
- AC with OT connector
- 24/7 monitoring
- with smart meter interface
- with RS485×2
- with AFCI (arc-fault protection)
- DC with Amphenol connectorOnly ASW150K-LT
OVERVIEW
ASW LT Series 125–150K
ASW LT series three-phase grid-tied inverter, 125–150kW, for large ground-mounted plants.
SPECIFICATIONS
Product comparison
ModelASW LT Series 125–150K
| Product comparison | |||
|---|---|---|---|
| Input (DC) | |||
| Max. PV array power | 187500 Wp STC | — | — |
| Max. input voltage | 1100V | 1100V | 1100V |
| MPP voltage range / rated input voltage | 200 V - 1000 V / 630V | 200 V - 1000 V / 630V | 200 V - 1000 V / 630V |
| Min. input voltage | 200V | 200V | 200V |
| Initial. feed-in voltage | 250V | 250V | 250V |
| Max. operating input current | 10*40A | 8*48A | 8*48A |
| Max. short circuit current | 10*50A | 8*60A | 8*60A |
| No. of independent MPPT inputs / strings per MPPT input | 10 / 2 | 8 / 3 | 8 / 3 |
| Output (AC) | |||
| Rated active power | 125000W | 150000W | 150000W |
| Rated apparent power | 125000VA | 150000VA | 150000VA |
| Max. apparent power | 137500VA | 150000VA | 150000VA |
| AC nominal voltage | 220 V / 380 V, 230 V / 400V | 380 V / 400V | 380 V / 400V |
| AC voltage range | 312 V - 528V | 312 V - 528V | 312 V - 528V |
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz |
| Nominal output current | 190.0A | 227.9A | 227.9A |
| Max. output current | 209.0A | 250.7A | 250.7A |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging |
| Feed-in phases | 3 / 3-N-PE | 3 / 3-N-PE | 3 / 3-N-PE |
| Harmonic distortion (THD) at rated output | ≤ 3% | ≤ 3% | ≤ 3% |
| Efficiency & Protection | |||
| Max. efficiency / European efficiency | 98.6 % / 98.4% | 99.0 % / 98.6% | 99.0 % / 98.6% |
| DC switch | Standard | Standard | Standard |
| Ground fault monitoring | Standard | Standard / Standard | Standard / Standard |
| Grid monitoring | Standard | Standard / Standard | Standard / Standard |
| DC reverse polarity protection | Standard | — | — |
| AC short-circuit protection | Standard | — | — |
| All-pole-sensitive residual-current monitoring unit | Standard | Standard | Standard |
| Anti-islanding protection | Standard | Standard | Standard |
| DC surge protection | Type II; Optional | Type II (Typel + II O) | Type II (Typel + II O) |
| AC surge protection | Type I+II; Optional | Type II (Typel + II O) | Type II (Typel + II O) |
| Arc Fault circuit interrupter (AFCI) | Standard | Standard | Standard |
| PID recovery | Optional | Optional | Optional |
| Protection class (according to IEC 62109-1) / Overvoltage category (according to IEC 62109-1) | I / AC: III; DC: II | I / AC: III; DC: II | I / AC: III; DC: II |
| Sunspec protocol (RTU) | Standard | Standard | Standard |
| General data | |||
| Dimensions (W / H / D) | 984 / 640 / 330mm | 1010 / 757 / 362mm | 1010 / 757 / 362mm |
| Weight | 87.0kg | 101.0kg | 101.0kg |
| Operating temperature range | -30 °C - 60°C | -30 °C - 60°C | -30 °C - 60°C |
| Self-consumption (at night) | < 5W | < 3W | < 3W |
| Topology | Non-isolated | Non-isolated | Non-isolated |
| Cooling concept | Active cooling | Active cooling | Active cooling |
| Degree of protection (according to IEC 60529) | IP66 | IP66 | IP66 |
| Relative humidity | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) |
| Max. operating altitude | 4000 m | 4000 m | 4000 m |
| Features | |||
| DC connector | Plug-in connector | Plug-in connector | Plug-in connector |
| AC connector | OT/DT connector | OT/DT connector | OT/DT connector |
| LED indicators (Status / Fault / Communication) | Standard | Standard | Standard |
| Communication interface | RS485 / Wi-Fi / LAN | RS485 / Wi-Fi / ABUS | RS485 / Wi-Fi / ABUS |
| Certificates and approvals (more available on request) | CE, IEC 62109-1/2, IEC 63027, IEC61727, EN50549 | CE, IEC 62109-1/2, IEC 63027, IEC 61727, EN 50549, IEC 62116, IEC 61683, IEC 61000 | CE, IEC 62109-1/2, IEC 63027, IEC 61727, EN 50549, IEC 62116, IEC 61683, IEC 61000 |
Product details

APPLICATIONS
Suitable for Multiple Scenarios
From individual equipment to an integrated energy system. Explore a solution around your site and project needs.
Explore Solutions
LET’S TALK ENERGY
Ready to Power Your Business?
Get in touch with our team to discuss your project requirements and find the best solution for your needs.