Grid-tied solar inverters
ASW LT Series 75–110kW
Three-phase grid-tied inverter, 75–110kW
ASW LT series three-phase grid-tied inverter, 75–110kW, for large commercial and ground-mounted plants.
- Max. PV array power112500 Wp STC / 120000 Wp STC etc. 4 types
- Max. input voltage1100 V
- MPP voltage range / rated input voltage200 V - 1000 V / 630 V
- Min. input voltage200 V
Max. PV array power
112500 Wp STC / 120000 Wp STC etc. 4 types
Max. input voltage
1100 V
MPP voltage range / rated input voltage
200 V - 1000 V / 630 V
Min. input voltage
200 V
Warranty
10 years
Product description
- 75–110kW
- 3P
- 8–10MPPT
- with Wi-Fi dongle
- 32A*8Only ASW75K-LT, ASW80K-LT
- DC with MOV surge protection
- AC with MOV surge protection
- DC with Vaconn connector
- AC with OT connector
- with SPS (backup power)
- with smart meter interface
- 32A*10Only ASW100K-LT, ASW110K-LT
OVERVIEW
ASW LT Series 75–110kW
ASW LT series three-phase grid-tied inverter, 75–110kW, for large commercial and ground-mounted plants.
SPECIFICATIONS
Product comparison
ModelASW LT Series 75–110kW
| Product comparison | |||
|---|---|---|---|
| Input (DC) | |||
| Max. PV array power | 112500 Wp STC | 120000 Wp STC | 150000 Wp STC |
| Max. input voltage | 1100V | 1100V | 1100V |
| MPP voltage range / rated input voltage | 200 V - 1000 V / 630V | 200 V - 1000 V / 630V | 200 V - 1000 V / 630V |
| Min. input voltage | 200V | 200V | 200V |
| Initial. feed-in voltage | 250V | 250V | 250V |
| Max. operating input current | 32A | 32A | 32A |
| Max. short circuit current | 48A | 48A | 48A |
| No. of independent MPPT inputs / strings per MPPT input | 8 / 2 | 8 / 2 | 10 / 2 |
| Output (AC) | |||
| Rated active power | 75000W | 80000W | 100000W |
| Rated apparent power | 75000VA | 80000VA | 100000VA |
| Max. apparent power | 75000W | 88000VA | 110000VA |
| AC nominal voltage | 220 V / 380 V, 230 V / 400V | 220 V / 380 V, 230 V / 400V | 220 V / 380 V, 230 V / 400V |
| AC voltage range | 312 V - 528V | 312 V - 528V | 312 V - 528V |
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz |
| AC nominal output current | 114.0A | 115.8A | 144.3A |
| Max. output current | 114.0A | 127.0A | 159.8A |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging |
| Feed-in phases | 3 / 3-N-PE | 3 / 3-N-PE | 3 / 3-N-PE |
| Harmonic distortion (THD) at rated output | < 3% | < 3% | < 3% |
| Efficiency & Protection | |||
| Max. efficiency / European efficiency | 98.6 % / 98.4% | 98.6 % / 98.4% | 98.6 % / 98.4% |
| DC switch | Standard | Standard | Standard |
| Ground fault monitoring / grid monitoring | Standard / Standard | Standard / Standard | Standard / Standard |
| DC reverse polarity protection / AC short circuit protection | Standard | Standard | Standard |
| AC Overcurrent Protection | Standard | Standard | Standard |
| DC Surge Protection | Type II | Type II | Type II |
| AC Surge Protection | Type II | Type II | Type II |
| Residual Current Monitoring Unit | Standard | Standard | Standard |
| Arc fault circuit interrupter (AFCI) | Optional | Optional | Optional |
| Anti-islanding Protection | Standard | Standard | Standard |
| Protection class (according to IEC 62109-1) / overvoltage category (according to IEC 62109-1) | I / AC: III; DC: II | I / AC: III; DC: II | I / AC: III; DC: II |
| General data | |||
| Dimensions (W / H / D) | 984 / 640 / 330mm | 984 / 640 / 330mm | 984 / 640 / 330mm |
| Weight | 86.0kg | 86.0kg | 86.0kg |
| Operating temperature range | -25 °C - 60°C | -25 °C - 60°C | -25 °C - 60°C |
| Self-consumption (at night) | < 3W | < 3W | < 3W |
| Topology | Non-isolated | Non-isolated | Non-isolated |
| Cooling concept | Active cooling | Active cooling | Active cooling |
| Degree of protection (according to IEC60529) | IP66 | IP66 | IP66 |
| Relative humidity | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) |
| Max. operating altitude | 4000 m | 4000 m | 4000 m |
| Features | |||
| DC connector | Plug-in connector | Plug-in connector | Plug-in connector |
| AC connector | OT/DT Terminal (Max.240mm²) | OT/DT Terminal (Max.240mm²) | OT/DT Terminal (Max.240mm²) |
| LED Indicators (Status / Fault / Communication) | Standard | Standard | Standard |
| 24/7 monitoring | Standard | Standard | Standard |
| Communication interface | RS485 / Wi-Fi / LAN | RS485 / Wi-Fi / LAN | RS485 / Wi-Fi / LAN |
| Modbus-Sunspec protocol | Standard | Standard | Standard |
| Certificates and approvals (more available on request) | CE, IEC 62109-1/2, IEC 61727, IEC61683, EN50549-1/2, VDE4105 | CE, IEC 62109-1/2, IEC 61727, IEC61683, EN50549-1/2, VDE4105 | CE, IEC 62109-1/2, IEC 61727, IEC61683, EN50549-1/2, VDE4105 |