Grid-tied solar inverters
ASW LT-G2 Pro Series 3–20kW
Three-phase grid-tied inverter, 3–20kW
ASW LT-G2 Pro series three-phase grid-tied inverter, 3–20kW, for commercial rooftop PV.
- Max. PV array power4500 Wp STC / 6000 Wp STC etc. 11 types
- Max. input voltage1100 V
- MPP voltage range / rated input voltage150 V - 1000 V / 630 V
- Min. input voltage125 V
Max. PV array power
4500 Wp STC / 6000 Wp STC etc. 11 types
Max. input voltage
1100 V
MPP voltage range / rated input voltage
150 V - 1000 V / 630 V
Min. input voltage
125 V
Warranty
10 years
Product description
- 3–20kW
- 3P
- 2MPPT
- with Wi-Fi dongle
- 16–32A*2Only ASW3K-LT-G2 Pro, ASW4K-LT-G2 Pro, ASW5K-LT-G2 Pro, ASW6K-LT-G2 Pro…
- DC with MOV surge protection
- AC with MOV surge protection
- DC with Vaconn connector
- AC with Vaconn connector
- with SPS (backup power)
- with smart meter interface
- with AFCI (arc-fault protection)
- 20A+16AOnly ASW8K-LT-G2 Pro, ASW10K-LT-G2 Pro
- 20A+32AOnly ASW12K-LT-G2 Pro, ASW13K-LT-G2 Pro, ASW15K-LT-G2 Pro
OVERVIEW
ASW LT-G2 Pro Series 3–20kW
ASW LT-G2 Pro series three-phase grid-tied inverter, 3–20kW, for commercial rooftop PV.
SPECIFICATIONS
Product comparison
ModelASW LT-G2 Pro Series 3–20kW
| Product comparison | |||
|---|---|---|---|
| Input (DC) | |||
| Max. PV array power | 4500 Wp STC | 6000 Wp STC | 7500 Wp STC |
| Max. input voltage | 1100V | 1100V | 1100V |
| MPP voltage range / rated input voltage | 150 V - 1000 V / 630V | 150 V - 1000 V / 630V | 150 V - 1000 V / 630V |
| Min. input voltage | 125V | 125V | 125V |
| Initial. feed-in voltage | 180V | 180V | 180V |
| Max. operating input current | 16 A / 16A | 16 A / 16A | 16 A / 16A |
| Max. short circuit current | 25 A / 25A | 25 A / 25A | 25 A / 25A |
| No. of independent MPPT inputs / strings per MPPT input | 2 / A:1;B:1 | 2 / A:1;B:1 | 2 / A:1;B:1 |
| Output (AC) | |||
| Rated active power | 3000W | 4000W | 5000W |
| Rated apparent power | 3000VA | 4000VA | 5000VA |
| Max. apparent power | 3000VA | 4000VA | 5000VA |
| AC nominal voltage | 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 220 V / 380 V, 230 V / 400 V, 240 V / 415V |
| AC voltage range | 160 V - 300V | 160 V - 300V | 160 V - 300V |
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz |
| Max. output current | 4.8A | 6.4A | 8.0A |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging |
| Feed-in phases | 3 / 3-N-PE | 3 / 3-N-PE | 3 / 3-N-PE |
| Harmonic distortion (THD) at rated output | < 3% | < 3% | < 3% |
| Efficiency & Protection | |||
| Max. efficiency / European efficiency | 98.3 % / 97.9% | 98.3 % / 97.9% | 98.3 % / 97.9% |
| DC Switch | Standard | Standard | Standard |
| Ground fault monitoring / grid monitoring | Standard / Standard | Standard / Standard | Standard / Standard |
| DC reverse polarity protection / AC short circuit protection | Standard / Standard | Standard / Standard | Standard / Standard |
| All-pole-sensitive residual-current monitoring unit | Standard | Standard | Standard |
| Arc fault circuit interrupter (AFCI) | Optional | Optional | Optional |
| Anti-islanding protection | Standard | Standard | Standard |
| Surge protection | Type II | Type II | Type II |
| Protection class (according to IEC 62109-1) / overvoltage category (according to IEC 62109-1) | I / AC : III ; DC : II | I / AC : III ; DC : II | I / AC : III ; DC : II |
| General data | |||
| Dimensions (W / H / D) | 503 / 435 / 183mm | 503 / 435 / 183mm | 503 / 435 / 183mm |
| Weight | 16.0kg | 16.0kg | 16.0kg |
| Operating temperature range | -25 °C - 60°C | -25 °C - 60°C | -25 °C - 60°C |
| Self-consumption (at night) | < 1W | < 1W | < 1W |
| Topology | Non-isolated | Non-isolated | Non-isolated |
| Cooling concept | Natural convection | Natural convection | Natural convection |
| Relative humidity | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) |
| Max. operating altitude | 3000 m | 3000 m | 3000 m |
| Degree of protection (according to IEC 60529) | IP66 | IP66 | IP66 |
| Features | |||
| DC connector | Plug-in connector | Plug-in connector | Plug-in connector |
| AC connector | Plug-in connector | Plug-in connector | Plug-in connector |
| Mounting type | Wall-mount bracket | Wall-mount bracket | Wall-mount bracket |
| LED indicators (Status / Fault / Communication) | Standard | Standard | Standard |
| 24/7 monitoring | Standard | Standard | Standard |
| Communication interface | RS485 / Wi-Fi / LAN | RS485 / Wi-Fi / LAN | RS485 / Wi-Fi / LAN |
| Certificates and approvals (more available on request) | CE, EN50549, G98/99, VDE-AR-N405, AS/NZS 4777, C10/C11, VFR 2014 & UTE C15, IEC62109, IEC62116, IEC61727, IEC61683, IEC61000, NB/T 32004 | CE, EN50549, G98/99, VDE-AR-N405, AS/NZS 4777, C10/C11, VFR 2014 & UTE C15, IEC62109, IEC62116, IEC61727, IEC61683, IEC61000, NB/T 32004 | CE, EN50549, G98/99, VDE-AR-N405, AS/NZS 4777, C10/C11, VFR 2014 & UTE C15, IEC62109, IEC62116, IEC61727, IEC61683, IEC61000, NB/T 32004 |
Product details

APPLICATIONS
Suitable for Multiple Scenarios
From individual equipment to an integrated energy system. Explore a solution around your site and project needs.
Explore Solutions
LET’S TALK ENERGY
Ready to Power Your Business?
Get in touch with our team to discuss your project requirements and find the best solution for your needs.