Grid-tied solar inverters
ASW LT-G3 Series 25–40kW
Three-phase grid-tied inverter, 25–40kW
ASW LT-G3 series three-phase grid-tied inverter, 25–40kW, for commercial rooftops and ground-mounted plants.
- Max. PV array power37500 Wp STC / 40500 Wp STC etc. 6 types
- Max. input voltage1100 V
- MPP voltage range / rated input voltage180 V - 1000 V / 630 V
- Min. input voltage160 V
Max. PV array power
37500 Wp STC / 40500 Wp STC etc. 6 types
Max. input voltage
1100 V
MPP voltage range / rated input voltage
180 V - 1000 V / 630 V
Min. input voltage
160 V
Warranty
10 years
Product description
- 25–40kW
- 3P
- 3MPPT
- with Wi-Fi dongle
- 32A*3Only ASW25K-LT-G3, ASW27K-LT-G3, ASW30K-LT-G3
- DC with MOV surge protection
- AC with MOV surge protection
- DC with Vaconn connector
- AC with Artila connector
- with SPS (backup power)
- with smart meter interface
- with AFCI (arc-fault protection)
- 32A*2+40AOnly ASW33K-LT-G3, ASW36K-LT-G3, ASW40K-LT-G3
OVERVIEW
ASW LT-G3 Series 25–40kW
ASW LT-G3 series three-phase grid-tied inverter, 25–40kW, for commercial rooftops and ground-mounted plants.
SPECIFICATIONS
Product comparison
ModelASW LT-G3 Series 25–40kW
| Product comparison | |||
|---|---|---|---|
| Input (DC) | |||
| Max. PV array power | 37500 Wp STC | 40500 Wp STC | 45000 Wp STC |
| Max. input voltage | 1100V | 1100V | 1100V |
| MPP voltage range / rated input voltage | 180 V - 1000 V / 630V | 180 V - 1000 V / 630V | 180 V - 1000 V / 630V |
| Min. input voltage | 160V | 160V | 160V |
| Initial. feed-in voltage | 200V | 200V | 200V |
| Max. operating input current | 32 A / 32 A / 32A | 32 A / 32 A / 32A | 32 A / 32 A / 32A |
| Max. short circuit current | 48 A / 48 A / 48A | 48 A / 48 A / 48A | 48 A / 48 A / 48A |
| No. of independent MPPT inputs / strings per MPPT input | 3 / A:2;B:2;C:2 | 3 / A:2;B:2;C:2 | 3 / A:2;B:2;C:2 |
| Output (AC) | |||
| Rated active power | 25000W | 27000W | 30000W |
| Rated apparent power | 25000VA | 27000VA | 30000VA |
| Max. apparent power | 25000VA | 27000VA | 30000VA |
| AC nominal voltage | 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 220 V / 380 V, 230 V / 400 V, 240 V / 415V | 220 V / 380 V, 230 V / 400 V, 240 V / 415V |
| AC voltage range | 180 V - 305 V / 312 V - 528V | 180 V - 305 V / 312 V - 528V | 180 V - 305 V / 312 V - 528V |
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz | 50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz |
| Max. output current | 39.9A | 43.0A | 47.8A |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging |
| Feed-in phases | 3 / 3-N-PE | 3 / 3-N-PE | 3 / 3-N-PE |
| Harmonic distortion (THD) at rated output | < 3% | < 3% | < 3% |
| Efficiency & Protection | |||
| Max. efficiency / European efficiency | 98.4 % / 98.2% | 98.4 % / 98.2% | 98.4 % / 98.2% |
| DC Switch | Standard | Standard | Standard |
| Ground fault monitoring / grid monitoring | Standard / Standard | Standard / Standard | Standard / Standard |
| DC reverse polarity protection / AC short circuit protection | Standard / Standard | Standard / Standard | Standard / Standard |
| All-pole-sensitive residual-current monitoring unit | Standard | Standard | Standard |
| Arc fault circuit interrupter (AFCI) | Optional | Optional | Optional |
| Anti-islanding Protection | Standard | Standard | Standard |
| Surge protection | Type II | Type II | Type II |
| Protection class (according to IEC 62109-1) / overvoltage category (according to IEC 62109-1) | I / AC: III; DC: II | I / AC: III; DC: II | I / AC: III; DC: II |
| General data | |||
| Dimensions (W / H / D) | 543 / 520 / 235mm | 543 / 520 / 235mm | 543 / 520 / 235mm |
| Weight | 29.0kg | 29.0kg | 29.0kg |
| Operating temperature range | -25 °C - 60°C | -25 °C - 60°C | -25 °C - 60°C |
| Self-consumption (at night) | < 1W | < 1W | < 1W |
| Topology | Non-isolated | Non-isolated | Non-isolated |
| Cooling concept | Active cooling | Active cooling | Active cooling |
| Degree of protection (according to IEC 60529) | IP66 | IP66 | IP66 |
| Relative humidity | 0 - 100% | 0 - 100% | 0 - 100% |
| Max. operating altitude | 3000 m | 3000 m | 3000 m |
| Features | |||
| DC connector | Plug-in connector | Plug-in connector | Plug-in connector |
| AC connector | Plug-in connector | Plug-in connector | Plug-in connector |
| Mounting type | Wall-mount bracket | Wall-mount bracket | Wall-mount bracket |
| LED Indicators (Status / Fault / Communication) | Standard | Standard | Standard |
| Communication interface | RS485 / Wi-Fi / LAN | RS485 / Wi-Fi / LAN | RS485 / Wi-Fi / LAN |
| Certificates and approvals (more available on request) | CE, EN50549, IEC62109, IEC62109, IEC61727, IEC62116, NB/T 32004 | CE, EN50549, IEC62109, IEC62109, IEC61727, IEC62116, NB/T 32004 | CE, EN50549, IEC62109, IEC62109, IEC61727, IEC62116, NB/T 32004 |
Product details

APPLICATIONS
Suitable for Multiple Scenarios
From individual equipment to an integrated energy system. Explore a solution around your site and project needs.
Explore Solutions
LET’S TALK ENERGY
Ready to Power Your Business?
Get in touch with our team to discuss your project requirements and find the best solution for your needs.