Grid-tied solar inverters

ASW MS Series 0.6–1kW

Single-phase grid-tied inverter, 0.6–1kW

ASW MS series single-phase grid-tied inverter, 0.6–1kW, for small residential PV systems.

  • Max. PV array power1500 Wp STC
  • Max. input voltage600 V
  • MPP voltage range / rated input voltage60 V - 560 V / 360 V
  • Full load MPP voltage range200 V - 500 V

Max. PV array power

1500 Wp STC

Max. input voltage

600 V

MPP voltage range / rated input voltage

60 V - 560 V / 360 V

Full load MPP voltage range

200 V - 500 V

Warranty

10 years

Product description

  • 1kW
  • 1P
  • 1MPPT
  • with Wi-Fi dongle
  • 16A
  • DC with MOV surge protection
  • AC with MOV surge protection
  • DC with Vacoon connector
  • AC with Vaconn connector
  • with smart meter interface

OVERVIEW

ASW MS Series 0.6–1kW

ASW MS series single-phase grid-tied inverter, 0.6–1kW, for small residential PV systems.

SPECIFICATIONS

Product comparison

ModelASW MS Series 0.6–1kW

ASW MS Series 0.6–1kW — Technical Specifications
Product comparisonASW1000-S-G2 · SA1000-12-23-38PASW1000-S-G2SA1000-12-23-38P
Input (DC)
Max. PV array power1500 Wp STC
Max. input voltage600V
MPP voltage range / rated input voltage60 V - 560 V / 360V
Full load MPP voltage range200 V - 500V
Min. input voltage60V
Initial. feed in voltage100V
Max. operating input current16A
Max. short circuit current24A
No. of independent MPPT inputs / strings per MPPT input1 / 1
Output (AC)
Rated active power1000W
Rated apparent power1000VA
Max. apparent power1000VA
AC nominal voltage220 V / 230 V / 240V
AC voltage range180 V - 295V
AC grid frequency / range50 Hz / 45 Hz - 55 Hz, 60 Hz / 55 Hz - 65 Hz
Max. output current5A
Adjustable power factor range0.8 leading - 0.8 lagging
Feed-in phases1
Harmonic distortion (THD) at rated output< 3%
Efficiency & Protection
Max. efficiency / European efficiency97.6 % / 97.1%
DC switchStandard
Ground fault monitoring / grid monitoringStandard / Standard
DC reverse polarity protection / AC short circuit protectionStandard / Standard
All-pole-sensitive residual-current monitoring unitStandard
Arc fault circuit interrupter (AFCI)Optional
Anti-islanding protectionStandard
Surge protectionType II
Protection class (according to IEC 62109-1) / overvoltage category (according to IEC 62109-1)I / AC: III; DC: II
General data
Dimensions (W / H / D)368 / 325 / 145mm
Weight9.5kg
Operating temperature range-25 °C - 60°C
Self-consumption (at night)< 1W
TopologyNon-isolated
Cooling conceptNatural convection
Degree of protection (according to IEC 60529)IP66
Relative humidity0 - 100 % (Non-condensing)
Max. operating altitude4000 m
Features
DC connectorPlug-in connector
AC connectorPlug-in connector
Mounting typeWall-mount bracket
LED Indicators (Status / Fault / Communication)Standard
24/7 monitoringStandard
Communication interfaceRS485 / Wi-Fi / LAN
Certificates and approvals (more available on request)IEC 62109-1/2, EN50549-1, C10/C11, VDE-AR-N 4105

Product details

ASW1000-S-G2

APPLICATIONS

Suitable for Multiple Scenarios

From individual equipment to an integrated energy system. Explore a solution around your site and project needs.

Explore Solutions

LET’S TALK ENERGY

Ready to Power Your Business?

Get in touch with our team to discuss your project requirements and find the best solution for your needs.

Scroll to zoom · Drag to pan · Double-click to reset

PRODUCT INQUIRY

Tell us about your project

Share your application and requirements, or start with a model from the list.

Exploring your options
Describe the installation site, power needs and project stage.
Have a model in mind
Include the model, key specifications or purchasing requirements.
Selected sample modelASW MS Series 0.6–1kW · ASW1000-S-G2 · SA1000-12-23-38P

After submission, the TOPWAY team will follow up using your contact details.

Let’s talk
Solar module product appearance

01 / SOLAR ENERGY

Solar

From building rooftops to wider spaces, explore solar module applications that make sunlight usable energy for every day.

RooftopsCommercial spacesSolar applications
Ask about this product